State GTS-110-NI User Manual

Page 38

Advertising
background image

 Troubleshooting 

38

Page

 

‐ 

WATE

R

 HEATER

 ‐

PROBLEM 

SOLUTIONS 

Unit does not ignite when 
water goes through the unit.

 

 Is the flow rate over 0.5 GPM? (p. 33) 
 Check for the filter on cold water inlet. (p. 36) 
 Check for reverse connection and cross connection. 
 If you use the remote controller, is the power button 

turned on?  

 Check if the inlet temperature is too high. 

The fan motor is still 
spinning after operation has 
stopped.

 

 

 This is normal. After operation has stopped, the fan motor 

keeps running from 15 to 70 seconds in order to re‐ignite 
quickly, as well as purge all the exhaust gas out of the flue.  

Unit sounds abnormal while 
in operation

 

 Contact the manufacturer at 1‐877‐737‐2840. 

‐Remo

te

 controll

er

‐ 

(OPTIONAL)

‐ 

Remote controller does not 
display anything when the 
power button is turned on. 

 Make sure the unit is supplied with power. 
 Make sure the connection to the unit is correct. (p. 22)  
‐9007603005 (TM‐RE30) only‐ 
If the green LED lights up, the remote controller has been 
turned ON.  When the unit has not operated for five minutes 
or more, the display turns off to conserve energy. 

An ERROR code is displayed.

 

 Please see p. 39‐41. 

‐EASY

‐LINK

 SYSTEM

‐  

510

  (T

‐D2)

 mod

e

ls

 on

ly

 

How are the unit numbers 
assigned? 

 
 
 
 

 
 
 
 
 

 
 
 

 For an Easy‐Link system, the Parent unit is always labeled 

#1 and all other subsequent Child units are numbered 
randomly. 

 To check which numbers are assigned to which Child units, 

push the button on the computer board of any Child unit 
as shown below.  The unit number will be displayed on the 
7‐Seg LED. (Refer to p.24 to 27) 

7‐Seg LED 

Button to check 
unit numbers 

When ON, green 
LED is lit. 