State GTS-110-NI User Manual

Page 41

Advertising
background image

 Troubleshooting 

41

Page

 

 

110 (T‐KJr2) 

and 310 (T‐K4) 

510 

(T‐D2)

Malfunction 
description
 

Diagnosis

 

Red 
LED 

Remote  Remote

N/A 

N/A 

441 

Flow Sensor 
Failure

 

(Easy‐Link 

System only)

 

 Check for connection/breakage of wires and/or debris 

on the flow sensor impeller. (Part #402, 717) 

Six

Times 

51 

510 

Abnormal Gas
Solenoid Valve

 

 Check for  connection/breakage  of  wires  (Part  #708) 

and/or  burn  marks  on  the  computer  board  (Part 
#701).

Six

Times 

55 

N/A 

Abnormal Main 

Gas Valve 

 Check for connection/breakage of wires (Part #708) 

and/or burn marks on the computer board (Part 
#701).

Four

Times 

61 

611 

Fan Motor Fault

 Check for connection/breakage of wires, dust buildup 

in the fan motor (Part #103) and/or burn marks on the 
computer board (Part #701).  

 Check for frozen/corrosion of connectors (Part #103).

N/A 

N/A 

651 

Flow 
adjustment 

Valve Fault  
(Easy‐Link 
System only)

 Inspect  the  flow  adjustment  valve  (Part  #402),  for 

connection/breakage  of  wires  (Part  #718),  locked 
motor  drive  due  to  scale  buildup,  and/or  water 
leakage. 

One 

Time 

70 

701 

Computer board 
Fault 

 Check  for  connection/breakage  of  wires  (Part  #714) 

and/or  burn  marks  on  the  computer  board  (Part 
#701). 

 Check the power supply of the water heater. 

Six 

Times 

72 

721 

False Flame 
Detection 

 For indoor models, check if condensate drain is 

installed on the vent collar of the water heater. 

 Check if there is leaking from heat exchanger (Part 

#401).

N/A 

74 

741 

Miscommunication 
between Water 
heater and remote 
controller 

 Check the model type of the remote controller. 

 Inspect  the  connections  between  the  water  heater 

and remote controller. 

 Check the power supply of the water heater. 

N/A 

N/A 

761 

Miscommunication in 
Easy‐Link system

 Check if the connections between the parent unit and 

the child units are correct. Refer to p.24 to 27.

Five 

Times 

99 

991 

Imperfect 
combustion 

 Check the gas type of the water heater.   

 Inspect the environment around the water heater.  

Determine how long the unit has been installed. 

 Check the altitude/elevation of the area of where the 

water heater installed. 

 Check if there is any blockage in the intake air and/or 

exhaust. 

 If the water heater is installed as a direct‐vent system, 

check whether there is enough distance between the 
intake air terminal and the exhaust terminal. 

 Check if there is grease and/or dirt in the burner (Part 

# 101) and the fan motor (Part # 104), especially if the 
water heater has been installed in a contaminated 
area. 

Advertising