Setting up

Walk Test Procedure

TIME - Fully anti-clockwise
DUSK - Fully clockwise

The unit will now operate during daytime as well as at
night, illuminating the lamp for approx. 5 seconds each
time. This allows testing to be carried out to establish
whether the sensor is covering the required area.
The lamp will immediately illuminate as the unit goes
through its "warm-up" period. After approximately 1 - 2
minutes the lamp will extinguish. Try to remain outside
the detection area during the warm-up period.
Walk around the sensor to establish the detection area.
The sensor will detect within an approximately six metre
diameter circle from the centre of the sensor location with a
2.5m ceiling.
As you cross a detection "zone" the lamp will illuminate.
Now stand still until the lamp extinguishes (this should
take approx. 5 seconds).
Start moving again. As you cross each "zone" the lamp
will illuminate.
Repeat the above, walking at various distances and
angles to the unit. This will help you to confirm the
detection pattern.

Please note that the function of L1 and L2 can be
viewed as a simple unconnected switch controlled by
the PIR sensor electronics.
When wiring is complete, set the two adjustment
controls on the side of the unit (diagram D) to the
following positions:
TIME -Fully anti-clockwise.
DUSK - Fully clockwise.
Push back the locating springs (diagram E) and feed
the unit into the ceiling void via the 75mm hole. The
locating springs will now fold back and hold the
SLFM360 in place.