11. PRODUCT

SPECIFICATION


Parameter Resolution

Accuracy

Range

Temp Measurement

Flue Temperature with
probe

1.0ºC/F +2.0ºC +0.3% reading

0-600ºC
32-1112ºF

Inlet Temperature

0.1ºC/F

+1ºC +0.3% reading

0-50ºC/32-122ºF

Pressure

0.01 mbar

+2% of full scale

+150mbar to -150mbar

Gas Measurement

*1

Oxygen 0.1%

+0.2% 0-21%

Carbon Monoxide

(standard: H compensated)

1ppm +20ppm <400ppm

+5%<5000ppm
+10%>5000ppm

0-10,000ppm

Carbon Monoxide

(high range)

0.01%

+

5% reading from 0.1%

to 10%

0 - 10%

Nitric Oxide

(standard)

1ppm +5ppm<100ppm

+5%>100ppm

0-5000ppm

Nitric Oxide

(low range)

1 ppm

+2ppm<30ppm
+5ppm>30ppm

0 -100ppm

Nitrogen Dioxide

1 ppm

+5ppm<100ppm
+10ppm<500ppm
+5%>500ppm

0 - 1000ppm

Sulphur Dioxide

1ppm

+5ppm<100ppm
+5%>100ppm

0-5000ppm

Calculations

Carbon Dioxide

*2

0.1% +0.3% reading

0-99.9%

Losses 0.1%

+1.0% reading

0-99.9%

Efficiency 0.1%

+1.0% reading

0-99.9%

Excess Air

0.1%

+0.2% 0-2885.0%

Temp (Nett)

1.0ºC/F

+2ºC +0.3% reading

0-600ºC/32-1112ºF

CO/CO

2

ratio 0.0001

+0.0001 0-0.9999

Poison Index

0.01%

+0.01 0-99.99

Pre-programmed
Fuels

Natural gas, Town gas, Gascor, Light Oil, Heavy Oil, Propane,
Butane, Anthracite, Coke, Coal, Kinsale Gas