7 chassis ground connection, Chassis ground connection – ADC 70 User Manual

Page 25

Advertising
background image

ADCP-80-524 • Issue 1 • November 2001

Page 25

©

2001, ADC Telecommunications, Inc.

4.7

Chassis Ground Connection

Mounting

the fuse panel on a metal equipment rack using the metal mounting brackets provided

with

the fuse panel provides a sufficient return path to meet equipment grounding requirements.

However,

a separate grounding conductor is often required by local practice or local inspectors.

A

separate chassis grounding conductor is always needed when the fuse panel is mounted to

non-grounded

or non-conducting material such as a plastic rack or cabinet. When the panel

requires

separate chassis grounding, the chassis grounding conductor must be sized to match the

upstream

protection device feeding the panel. This provides an adequate return path capable of

allowing

the fuse to fail in the unlikely event of a battery wire to chassis fault.

Connect

one or both of the chassis ground connectors (labeled C. GND) to the equipment rack

ground

(see

Figure 19

),

using the following chassis grounding recommendations:

• Chassis

grounding conductor connection point: Two #10 studs (with nuts) on 0.625 inch

(15.875 mm)

centers are provided for connecting a grounding conductor to the fuse panel.

• Chassis

ground conductor: Use two #10 AWG wires if using both chassis ground

connectors

or one #6 AWG wire if using one chassis ground connector. Two #10 crimp

ring

terminals (for use with #10 AWG wires) are included with the fuse panel.

• Place

the ring terminals over the chassis grounding studs and tighten the stud nuts to

approximately

15 pound-force inches (1.7 Newton meters) of torque.

• Connect

the ground conductors to an approved office ground source per local code or

practice.

Figure 19. Chassis Ground Connection

USE TWO #10 AWG WIRES IF USING BOTH CHASSIS GROUND CONNECTORS OR ONE #6 AWG WIRE IF USING ONLY ONE
CHASSIS GROUND CONNECTOR.

TWO #10 CRIMP RING TERMINALS FOR ATTACHING THE #10 WIRES TO THE CHASSIS CONNECTORS ARE PROVIDED
WITH THE FUSE PANEL.

PLACE THE RING TERMINALS OVER THE CHASSIS SCREWS AND TIGHTEN THE NUTS DOWN ON THE TERMINALS. IF NOT
USING TERMINALS, WRAP THE WIRE(S) AROUND THE CHASSIS SCREW(S) AND TIGHTEN THE NUTS DOWN ON THE WIRES.
CONNECT THE WIRE(S) TO THE EQUIPMENT RACK.

GROUND SCREW AND NUT

GROUND SCREW AND NUT

16160-A

Advertising