d

Using the enclosed Allen wrench (3 mm),
turn the four hexagonal screws outside the
ring one turn in the direction of the arrow to
loosen them.

1

Hexagonal screws

2

Enclosed Allen wrench (3 mm)

X

When the hexagonal screws are loosened,
the ring can be lowered.

Memo

● Do not remove the hexagonal screws.

e

While lightly pressing down on the ring, so
that the spacing between the ring and the
bed are equal on the left and right sides, use
the Allen screwdriver (3mm) to evenly
tighten the opposite hexagonal screws on
the outside of the ring, and then tighten the
other two hexagonal screws.
Firmly tighten all 4 screws.

1

Ring

2

Hexagonal screws

Note

● If the screws are not firmly tightened, the

cylinder frame driver may be damaged.

● To avoid damage to the machine or fabric,

make sure that no excess material is
allowed into the gap.

Installing the needle plate spacer

Attach the needle plate spacer (included with the
machine) to the needle plate.

1

Needle plate spacer

Preparing the cylinder frame mounting jig

Attach the cylinder frame mounting jig to a level,
stable surface, such as a desk.

a

Loosen the mounting jig thumb screw to
increase the space in the mounting bracket
so that it is wider than the thickness of the
mounting surface.

1

Mounting bracket

2

Open to desired width.

3

Thumb screw

• The mounting bracket can be attached to a

surface 9 to 38 mm (11/32 to 1 1/2 inches)
thick.

a

a

b

a

b

b

a

a

b

c