Brother NC-7100W User Manual

Page 106

Advertising
background image

TCP/IP CONFIGURATION 9 - 12

You will then get the

Local>

prompt. Type

SET IP ADDRESS

ipaddress

, where

ipaddress

is the desired IP address you wish

to assign to the print server (check with your network manager for the
IP address to use). For example:

Local> SET IP ADDRESS 192.189.207.3

You will now need to set the subnet mask by typing

SET IP SUBNET

subnet mask

, where

subnet mask

is the desired subnet mask

you wish to assign to the print server (check with your network
manager for the subnet mask to use). For example:

Local> SET IP SUBNET 255.255.255.0

If you do not have any subnets, use one of the following default
subnet masks:

255.255.255.0

for class C networks

255.255.0.0

for class B networks

255.0.0.0

for class A networks

The leftmost group of digits in your IP address can identify the type
of network you have. The value of this group ranges from 192
through 255 for Class C networks (e.g., 192.189.207.3), 128 through
191 for Class B networks (e.g.,128.10.1.30), and 1 through 127 for
Class A networks (e.g., 13.27.7.1).

If you have a gateway (router), enter its address with the command

SET IP ROUTER routeraddress

, where

routeraddress

is the

desired IP address of the gateway you wish to assign to the print
server. For example:

Local> SET IP ROUTER 192.189.207.1

Type

SET IP METHOD STATIC

to set the method of IP access

configuration to static.

To verify that you have entered the IP information correctly, type

SHOW IP

.

Type

EXIT

or CTR-D (i.e., hold down the control key and type "D")

to end the remote console session.