P. 2-9, Use of external power supply, This completes the network connection – Canon VB-C60 User Manual

Page 51

Advertising
background image

2-9

Step 2 Connect the Camera to the Network

Init
ial S

e

tting and

Ins

ta

llati
o

n

of Cam

e

ra

Use of External Power Supply

An AC adapter, 12-VDC input or 24-VAC input can be used as an external power supply.

Connect the supplied power connector ( P. x) as shown in the figure below.

Use a 12-VDC or 24-VAC power supply insulated from 100 VAC.

12 VDC can be connected in a non-polar condition. Use the power supply within the following

voltage range.

24 VAC:

Voltage fluctuation 24 VAC

±

10% or less

(50 or 60 Hz

±

0.5 Hz or less)

Current supply capacity per camera 1.0 A or more

12 VDC:

Voltage fluctuation 12 VDC

±

10% or less

Current supply capacity per camera 1.5 A or more

* If a 12-VDC battery power supply is used, be sure to connect a resistor of 0.5 to 1.0 Ω/20 W

or more to the power line.

* Use double-insulated devices for the external power supply.

Recommended Power Cable of VB-C60 [Reference]

This completes the network connection.

Cable (AWG)

conductor size

(Φmm, Φinch)

#24

(0.52 mm)

(0.020inch)

#22

(0.65 mm)

(0.026inch)

#20

(0.82 mm)

(0.032inch)

#18

(1.03 mm)

(0.041inch)

#16

(1.30 mm)

(0.051inch)

Maximum cable length,

12 VDC (m, ft)

5

(16.4)

9

(29.5)

14

(45.9)

23

(75.4)

32

(105.0)

Maximum cable length,

24 VAC (m, ft)

11

(36.1)

18

(59.0)

29

(95.1)

46

(151.0)

64

(210.0)

Use a UL cable (UL-1015 or equivalent) for wiring 12 VDC or 24 VAC.

Screwdriver
Tightening torque:
0.2 N·m (1.77lbf·in) (max.)

Stripping length

approx. 4mm - 6mm
(0.16inch - 0.24inch)

Power Connector
(Supplied)

Advertising