External device output terminals (out1, out2), Internal connection diagram – Canon VB-C60 User Manual

Page 74

Advertising
background image

3-6

Input/Output Terminals

External Device Output Terminals (OUT1, OUT2)

There are two sets of external device output terminals (OUT1, OUT2), where each set consists of

two terminals. Each terminal set has no polarity. The condition between the two terminals can be

switched between connected and disconnected by controlling from the viewer. The output

terminals are isolated from the internal circuits of the camera using optical couplers.

The loads connected to the output terminals should be used within the following ratings:

Ratings between output terminals: Maximum voltage 50 VDC

Continuous load current 100 mA max.

Internal Connection Diagram

Tip

Applicable wire for external device cable

Single AWG No.28 to 22

Conductor size Φ0.32 to 0.65 (mm) (0.013 to 0.026 in)

Strip the cable by approx. 8 to 9 mm (0.315 to 0.354 in).

Inter

nal controller

External
device

External
device

Input terminal

IN1, IN2

Output terminal

OUT1, OUT2

10k

Ω

10k

Ω

10k

Ω

+3.3V

+

-

0.1

µ

F

Advertising