22

Connecting gas dryers (cont.)

w

WarnInG

To reduce the risk of fire, electric shock, or injury to persons when

using this appliance, follow basic precautions, including the

following:

Installation and service must be performed by a qualified

installer, service agency, or the gas supplier. Failure to do so

can result in fire, explosion, or death.

Use only a new stainless steel flexible connector and a new

AGA-certified connector. Failure to do so can result in fire,

explosion, or death.

A gas shutoff valve must be installed within 6 ft. (1.8 m) of

the dryer. Failure to do so can result in fire, explosion, or death.

The dryer is configured for Natural Gas when shipped from

the factory. Make sure that the dryer is equipped with the

correct burner orifice for the type of gas being used (Natural

Gas or Liquefied Petroleum). Failure to do so can result in fire,

explosion, or death.

If necessary, the correct orifice (for the LP orifice kit, order

part number 383EEL3002D) should be installed by a

qualified technician and the change should be noted on the

dryer. Failure to do so can result in fire, explosion, or death.

All connections must be in accordance with local codes and

regulations. Failure to do so can result in fire, explosion, or

death.

Gas dryers MUST exhaust to the outdoors. Failure to do so can

result in fire, explosion, or death.

connecting the gas supply

1. Make sure that the gas supply to the laundry room is turned

OFF. Confirm that the type of gas available in your laundry room
is appropriate for the dryer. The dryer is prepared for Natural
Gas with a

3

⁄₈ - inch NPT gas connection.

2. Remove the shipping cap from the gas connection at the back

of the dryer. Be careful not to damage the threads of the gas
connector when removing the shipping cap.

3. Connect the dryer to your laundry room’s gas supply using a

new flexible stainless steel connector with a

3

⁄₈ - inch NPT fitting.

4. Securely tighten all connections between the dryer and your

laundry room’s gas supply. Turn on your laundry room’s gas
supply and check all pipe connections (both internal and
external) for gas leaks with a noncorrosive leak-detection fluid.

electrical connection

high-altitude installations

The BTU rating of this dryer is AGA-certified for elevations below
10,000 feet.
If your gas dryer is being installed at an elevation above 10,000
feet, it must be derated by a qualified technician or gas supplier.

Plug dryer into a 120 VAC,
60 Hz
grounded 3-prong outlet.

3/8” NPT Gas
Connection

Gas Supply
Shutoff Valve

1/8” NPT Pipe
Plug

AGA/CSA-Certified
Stainless Steel Flexible
Connector

InstallatIon InstrUCtIons

InstallatIon InstrUCtIons