Installation test (exhaust check) (cont.) – LG DLG3051W User Manual

Page 30

Advertising
background image

30

InstallatIon InstrUCtIons

hoW to UsE

Installation test (Exhaust check) (cont.)

Restricted or blocked airflow

Avoid long runs or runs with multiple elbows or

bends.

Excess or crushed

transition duct

Too many elbows or

exhaust too long

Check for blockages and lint buildup.

Make sure the ductwork is not crushed or restricted.

Crushed or

damaged

exhaust

• Check the error code before you call for service

• Check the duct condition

If the test displays four bars, check the exhaust system for re-
strictions and damage. Repair or replace the exhaust system as
needed.

When the dryer is first installed, this test should be performed to
alert you to any existing problems with the exhaust duct in your
home. However, since the test performed during normal
operation provides more accurate information on the condition
of the exhaust duct than does the installation test, the number of
bars displayed during the two tests may not be the same.

Do not interrupt the test cycle, as this could result in the wrong
results.

Even if no bars are displayed during the test cycle, some
restrictions may still be present in the exhaust system. Refer to the

Venting the dryer section of this manual for complete exhaust
system and venting requirements.

Your dryer features Flow Sense™, an innovative sensing system
that automatically detects blockages and restrictions in dryer
ductwork. Keeping ductwork clean of lint buildup and free of
restrictions allows clothes to dry faster and reduces energy use.

Error Code

Possible Causes

Solutions

tE1 or tE2

Temperature sensor failure

Turn off the dryer and call for

service.

HS

Humidity sensor failure.

Turn off the dryer and call for

service.

PS or PF or nP

Electric dryer power cord is not

connected correctly, or house power

supply is incorrect.

House fuse is blown, circuit breaker has

tripped, or power outage has occurred.

Check the power supply or the

connection of power cord to the

terminal block. Refer to the

Connecting electric dryers section of

this manual for complete instructions.

• Reset circuit breaker or replace fuse.

Do not increase the fuse capacity.

If the problem is a circuit overload,

have it corrected by a qualified

electrician.

Lint buildup or

blockage

notE

Advertising
This manual is related to the following products: