InstallatIon InstrUCtIons

InstallatIon InstrUCtIons

Connecting electric dryers (cont.)

USA only

four-wire connection for electric dryers:

power cord

• A 4-wire connection is required for all mobile and manufactured

home installations, as well as all new construction after January 1,

1996.

• A UL-listed strain relief is required.

1. Remove the terminal block access cover on the upper back of

the dryer. Install a UL-listed strain relief into the power cord
through-hole; then thread a UL-listed, 30 A, 240 V, 4-wire, #10
AWG-minimum copper
conductor power cord through the
strain relief.

Use a 30 A, 240 V, UL-listed power cord with #10 AWG-

minimum copper conductor and closed loop or forked

terminals with upturned ends.

2. Transfer the dryer’s ground wire from behind the green ground

screw to the center screw of the terminal block. Attach the two

hot leads of the power cord to the outer terminal block screws.

Attach the white neutral wire to the center terminal block

screw. Attach the power cord ground wire to the green ground

screw. TIGHTEN ALL SCREWS SECURELY. Reinstall the terminal

block access cover.

UL-Listed

Strain Relief

UL-Listed

4-Wire Power

Cord

Terminal

Block

w

WarnInG

Connect the power cord to the terminal block. Each

colored wire should be connected to same color screw.

Wire color indicated on manual is connected to the same

color screw in block. Failure to follow these instructions

may result in a short or overload.

Grounding through the neutral conductor is prohibited

for: (1) new branch-circuit installations, (2) mobile homes,

(3) recreational vehicles, and (4) areas where local codes

prohibit grounding through the neutral conductor.

Neutral

(White)

Hot

(Black)

Hot

(Red)

Power Cord

Ground Wire

Ground

Screw

White Wire

moved from

Ground Screw