Additional controls, Operating instructions, Notice – LG LP090HEM User Manual

Page 10

Advertising
background image

10

GL GH

O

W

Y

R

C

LO LI

Front Desk Switch

LO LI GL GH

O

W

Y

R

C

Low Fan

High Fan

Reversing Valve

Heater

Compressor

24 Volt-L

24 Volt-N

Wiring Schematic for
Remote Heat Pump

Wiring Schematic for
Straight Cool Unit.

Additional Controls

Operating
Instructions

When the pair wire is connected to the connector LOand LI, the unit can be turned ON or OFF with a switch
located at the Front Desk Control panel. When the front desk switch is ON, the fan operate according to the
condition of setting without working compressor and heater. When the front desk switch is OFF, the unit can
operate according to the setting of controls.

When the wires are connected, the unit will be controlled by a remote
wall thermostat.

The thermostat connections supply the 24 Volt AC. When you install
the digital / electronic thermostat, you must set it to the 24 Volt AC.
See the installation Instruction in this manual for the Remote Wall
Thermostat.

Front Desk Control

Remote Wall Thermostat

Remote/Local Control

Energy Saver

When remote/local switch #1 is on, it allow the unit to operate by the control of Remote Wall Thermostat.

The unit control by knobs are not available.

The energy saver switch #2 is on. This switch is set at continuous fan to provide continuous fan operation in cool
or heat modes. When the switch is off the continuous fan allows continuous circulation of room air and make the
more balanced temperature of the room. When the switch is on the fan is on or off with the compressor or with
the heater.

Wire # AWG

Maximum Length

#22

600ft(180m)

#20

900ft(270m)

#18

1500ft(450m)

#16

2000ft(610m)

The following figures show wiring
schematics for heat pump and
straight cool units with electric
heat, respectively.