Additional controls, English, Remote control operations temperature limiting – LG LP090HEM User Manual

Page 9: Removing the front grille additional controls, Operating instructions

Advertising
background image

9

ENGLISH

Temperature Limiting can save money by limiting the lowest temperature for cooling and the highest temperature
for heating. The temperature limiting is controlled by dip switch #1 - #3.

This temperature limiting is not available with the Remote Wall Thermostat.

Remote Control Operations

Temperature Limiting

OFF

OFF

OFF

54°F (12.2°C)

86°F (30.0°C)

54°F (12.2°C)

86°F (30.0°C)

ON

OFF

OFF

56°F (13.3°C)

86°F (30.0°C)

54°F (12.2°C)

84°F (28.9°C)

OFF

ON

OFF

58°F (14.4°C)

86°F (30.0°C)

54°F (12.2°C)

82°F (27.8°C)

ON

ON

OFF

60°F (15.5°C)

86°F (30.0°C)

54°F (12.2°C)

80°F (26.7°C)

OFF

OFF

ON

62°F (16.6°C)

86°F (30.0°C)

54°F (12.2°C)

78°F (25.5°C)

ON

OFF

ON

64°F (17.7°C)

86°F (30.0°C)

54°F (12.2°C)

76°F (24.4°C)

OFF

ON

ON

66°F (18.9°C)

86°F (30.0°C)

54°F (12.2°C)

74°F (23.3°C)

ON

ON

ON

68°F (20.0°C)

86°F (30.0°C)

54°F (12.2°C)

72°F (22.2°C)

Temperature Temperature Temperature

Limit #1

Limit #2

Limit #3

Lowest Temp.

Highest Temp.

Lowest Temp.

Highest Temp.

Cooling Operation

Heating Operation

ON

ON

REMOTE

OFF

ON

ON

ON

Remote/Local
Energy Saver
Temperature Limit 1
Temperature Limit 2
Temperature Limit 3

LOCAL

1

OFF

2

OFF

3

OFF

4

OFF

5

LOCAL

1

OFF

2

OFF

3

OFF

4

OFF

5

LOCAL

1

OFF

2

OFF

3

OFF

4

OFF

5

LOCAL

1

OFF

2

OFF

3

OFF

4

OFF

5

Additional Controls

Operating
Instructions

Removing the Front Grille

Additional Controls

Additional controls are available after removing the
front grille and option cover of control box.

To remove the front grille, pull out the bottom of front
grille and then lift up.

To replace the front grille, place the tabs over the top of
the unit and push the bottom of front grille until the clips
snap into place.

The additional controls are located behind the option cover of control box. The standard settings will be in the
OFF position. The authorized service man has to check switches and ensure the switches are in the desired
position.

Advertising