Caution, Hardware installation, English how to install the unit – LG LP090HEM User Manual

Page 15: Notice

Advertising
background image

406 mm

(16")

406 mm

(16")

1,066 mm

(42")

1066 mm

(42")

318 mm
(12

1

/

2

")

318 mm
(12

1

/

2

")

505 mm

(20")

Over 20"

HEAT

RADIATION

WALL

WALL

INSULATION

SLEEVE

INTAKE

AIR

COOLED

AIR

1/4" Bubble

of the level

Front

Insulation Strip

Rear

Sleeve

280 mm

(11")

Dimension of air conditioner

Dimension of sleeve assembly (optional)

Hardware Installation

Hardware
Installation

15

ENGLISH

How to Install the Unit

• There are sharp edges that can cause serious cuts.

• When lifting the air conditioner, it is HEAVY.

Use 2 people to lift.

For existing sleeve, you should measure the wall sleeve
dimensions.

You can install the new air conditioner according to these
installation instructions to achieve the best performence. All
wall sleeves used to mount the new air conditioner must be
in good structural condition and have the rear grille that
securely attaches to the sleeve or the flange of the sleeve to
secure the new air conditioner.

• To avoid vibration and noise, make sure the unit is

installed securely and firmly.

When installing the sleeve, make certain there is nothing
within 20" of the back that would interfere with heat radiation
and exhaust air flow.

To maintain the best performance of

the LG PTAC, an insulation strip
must be attached. The insulation
strip is provided with the box.
Refer to the diagram below.

1) Take out the insulation strip from the upper packing.

2) Attach the insulation strip onto the rear upper side of the

wall sleeve.

3) If anyone would like to improve unit energy efficiency, it is

recommended the change of outside grille for an unit
protection and an addition of a plastic rear grille. (This is
optional.)

NOTICE

CAUTION

Advertising