Hardware installation, Electrical data, Notice – LG LP090HEM User Manual

Page 16: The shape may be different according to its model

Advertising
background image

16

Electrical Data

Hardware Installation

Hardware
Installation

115V~

230V~

265V~

Power cord may include a current
interrupter device. A test and reset
button is provided on the plug case. The
device should be tested on a periodic
basis by first pressing the TEST button
and then the RESET button. If the TEST
button does not trip or if the RESET
button will not stay engaged,
discontinue use of the air conditioner
and contact a qualified service
technician.

Use Wall Receptacle

Power Supply

Standard 208/230V, 3-wire

grounding receptacle rated 15A

Standard 208/230V, 3-wire

grounding receptacle rated 20A

Use 15 AMP. time
delay fuse or 15 AMP.
Circuit breaker.

Use 20 AMP. time
delay fuse or 20 AMP.
Circuit breaker.

(2500W Heater

→15Amp

Circuit Breaker)

(2000W Heater

→15Amp

Circuit Breaker)

Use 30 AMP. time
delay fuse or 30 AMP.
Circuit breaker.

Standard 208/230V, 3-wire

grounding receptacle rated 30A

Use 20AMP,time delay
fuse or 20AMP
Circuit breaker

Standard 265V grounding

receptacle rated 20A

Use 25AMP,time delay
fuse or 25AMP
Circuit breaker

Standard 265V grounding

receptacle rated 25A

The shape may be different according to its model.

NOTICE

DO NOT USE AN EXTENSION CORD on 230,
208, and 230/208,265Volt units.
All wiring should be made in accordance with
local electrical codes and regulations.
Aluminum house wiring may pose special
problems. Consult a qualified electrician.

NOTICE

Never push the test button during operation
Otherwise this plug can damaged.
This device contains chemicals, including lead, known
to the State of California to cause cancer, birth
defects, or other reproductive harm.
Wash hands after handling.
Do not remove, modify, or immerse this plug.
If this device trips, the cause should be corrected
before further use.

The conductors inside this cord are surrounded by shields,
which monitor leakage current.
These shields are not grounded.
Periodically examine the cord for any damage. Do not use
this product in the event the shields become exposed.
Avoid shock hazard! This unit cannot be serviced. Opening
the tamper-resistant, sealed portion of the unit voids all
warranties and performance claims. This unit is not intended
to be an ON/OFF switch.

• If unit equipped with cords and plugs as long as they are

installed with sub-bases, and the cord and plug are
enclosed within the sub-base.

• The sub-base must have means for permanent

connection.

• The sub-base must have an outlet for the connection of

the cord and plug.

• To complete the installation of this PTAC, there must be a

sub-base.

Advertising