Job description, Dicom print ae, Parameters – AGFA HE/001132 User Manual

Page 64

Advertising
background image

HE/001132

Page 64 of 92

Document No. 001132, Revision 2.0

Agfa HealthCare

NodeID Livelink : 14140190

14 June, 2007

on forward the images to the PACS. A DICOM Store queue can only be rerouted to another DICOM Store
queue with

- The same output type configured (this includes the SOP class to be used)
- The same GSPS support

If the new destination is configured for Storage Commitment, the storage commit request will be sent to the
new destination when processing the job.

By means of a

SENT-flag, an image that has already been successfully sent to a specific archive cannot be

sent to that archive twice. The SENT-flag can be applied to all DICOM store destinations, including both the
archive and the other softcopy destinations (e.g. viewing stations).

2.4.1.4.2

Job description

One archive job can contain multiple images. All these images and their GSPS’s will be sent to the archive
through a single association.

The user can perform the following actions on existing jobs: “Delete job” and “Expedite job”

When an image in the archive job does not reach its destination, or when the storage commit replies “time
out”, the job is FAILED. .

2.4.1.5

DICOM Print AE

There is only one entry per print job (with possible multiple sheets) in the queue.
All queue actions are done on one print job: retry, reprint, expedite, …

2.4.2

Parameters

The specification of important operational parameters, and if configurable, their default value and range, are
specified in the table below.

The parameters that apply to all Application Entities are specified in the “General Parameters” section. Those
specific to particular Applications are specified in separate sections specific to each AE.

Table 2.4-5: Configurable Parameters for "Workstation".

Parameter

Configurable
(yes/no)

Default value

General Parameters

Max PDU Receive Size

No

65542

Max PDU Send Size (larger PDUs will never be
sent, even if the receiver supports a larger Max PDU
Receive Size. If the receiver supports a smaller Max
PDU Receive Size then the Max PDU Send Size will
be reduced accordingly for the duration of the
Association. Max PDU Receive Size information is
exchanged during DICOM Association Negotiation in
the Maximum Length Sub-Item of the A-
ASSOCIATION-RQ and A-ASSOCIATE-AC)

No

65542