Agilent Technologies HDMP-3001 User Manual

Page 116

Advertising
background image

116

8.10 Reset specification
The HDMP-3001 reset pin (RSTB)
is an asynchronous pin that must
be active for at least 200 SONET
clock cycles (>10

µ

s) with stable

power.

TX_CLK

TX_D[3:0], TX_EN, TX_ER

RX_D[3:0], RX_DV, RX_ER

RX_CLK

t

TX

0 ns MIN., 25 ns MAX.

t

RXS

10 ns MIN.

t

RXH

10 ns MIN.

VALID

VALID

Figure 38. MII timing as defined by IEEE 802.3

8.11 MII Timing
HDMP-3001 meets the MII timing
as defined by IEEE 802.3 as
shown in Figure 38.