8

Pin 4

Line Lock

Pin 5

System Initialization (for

upgrade)

Pin 6

Reserved

RS-232 is reserved for internal use only; The Pin 3 and Pin 4, they

are used for termination and Link Lock adjustment respectively.

The Pin 5 is mainly used for return to factory default of camera

setting.

3.

Dome ID Setting

Use the switch to change your speed dome ID by turning the

arrow to the desired number respectively. For instance, if the

speed dome ID is 123, the ID switch should be set as below:

centesimal decimal

single digit

d

o

4.

Dome Control Protocol

Protocol is a specific set of rules, procdures used for data

communications. Basing on the protocol of your management

software that you are going to use. Use the switch to set your

dome control protocol and the baud rate. Refer to table below and

turn the arrow to choose a protocol for your speed dome.

Switch No.

Protocol

Baud Rate

01

Pelco D

2400

02

Pelco P

4800

07

DSCP 9600

11

Pelco D

4800

12

Pelco D

9600

13

Pelco P

2400

NOTE:

No two speed domes should be given the same ID, or

communication conflict may occur.

NOTE:

The number “0” should locate upwards as shown in

above diagram for correct switch definition.