ALARM ACTION

Select one of these modes that choose a kind of actions that should be

executed when an alarm is triggered. The alarm actions can be set to execute

the preset position, sequence, auto-pan or cruise function.

PRESET

Select a preset point where the dome should go when an alarm pin is

triggered.

SEQUENCE

Select a sequence line that the speed dome camer should execute when alarm

pin is triggered. The Sequence line should be defined prior in SEQENCE

setup menu.

AUTOPAN

Select an auto-pan line that the dome camera should execute when alarm pin

is triggered. The Auto-pan line can be defined in setup AUTOPAN menu.

CRUISE

Select a cruise line that the speed dome camera should execute when alarm

pin is triggered. The Cruise line can be defined in CRUISE setup menu.

DWELL TIME

The DWELL TIME is the duration of executing ALARM ACTION: Preset

or Sequence. When alarm takes place, the dome will go to the preset position

or execute sequence function and stay at each sequence point for a period of

time (1~127 seconds). If select <Always>, the dome will go to the preset

position and stay there until alarm condition is released or users rotate the

dome.


EXIT

Exit the ALARM SETTING menu.