HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 8

Advertising
background image

Introduction 8

Command

Changes

Virtual Connect 4.10 Virtual Connect 4.20

add port-monitor

remove port-monitor

set port-monitor

Modified the

commands to include
QSFP+ uplink ports in
the AnalyzerPort

property

add port-monitor

[AnalyzerPort=<Por

tID>]

[Speed=<Auto|10Mb|

100Mb|1Gb|10Gb|Dis

abled>]

[Duplex=<Auto|Half

|Full>]

[MonitorPort=<Port

ID>]

[Direction=<ToServ

er|FromServer|Both

>]

where the format of the

network analyzer
<PortID> is

<EnclosureID>:<Int

erconnectBay>:<Por

tNumber>

add port-monitor

[AnalyzerPort=<Por

tID>]

[Speed=<Auto|10Mb|

100Mb|1Gb|10Gb|40G

b|Disabled>]

[Duplex=<Auto|Half

|Full>]

[MonitorPort=<Port

ID>]

[Direction=<ToServ

er|FromServer|Both

>]

where the format of the

network analyzer
<PortID> is

<EnclosureID>:<Int

erconnectBay>:<Por

tNumber>.

For QSFP+ ports, the
<PortNumber> format is

Q<x>.<y>.

add port-monitor

set port-monitor

add uplinkport

set uplinkport

Modified the

commands to include
the "40Gb" speed

type

[Speed=<Auto|10Mb|

100Mb|1Gb|10Gb|Dis

abled>]

[Speed=<Auto|10Mb|

100Mb|1Gb|10Gb|40G

b|Disabled>]

show config

The

includePoolInfo

option provides

VC-defined
addresses and

user-defined

addresses for
profiles, to be used to

restore the profiles

while maintaining the
pool-specified IDs.

Not available

Available

add profile

add enet-connection

add fc-connection

add fcoe-connection

add iscsi-connection

The

PoolSpecified

option supports

creating a profile and

its connections with
pool-specified

addresses, if

available in the

specified domain
pool.

Not available

Available

show interconnect

The

-fip_snooping

option displays FIP

snooping information

for the specified
interconnect module.

Not available

Available