Comments, New settings can affect other settings, Lun manager spreadsheet settings – HP StorageWorks XP Remote Web Console Software User Manual

Page 150: 150 new settings can affect other settings, Sample configuration definitions, Lun manager, Spreadsheet settings, Figure 108

Advertising
background image

Figure 108 Sample Configuration Definitions

.

Comments

You can also type comment rows in the spreadsheet by beginning a row with the # character. The
comment row can consists of any characters in any language. A row that includes only a linefeed
code is also recognized as a comment row.

Example:
# (comment)
# Change CHA settings (comment)
[CHA](function tag)
# CHA,PCB Mode (comment)
# (linefeed)
# (linefeed)
CHA-1P,Standard (indicating changes)
CHA-1Q,Standard (indicating changes)

New Settings Can Affect Other Settings

As a general rule, the settings are applied to the array one at a time, in the order they appear in the
spreadsheet. This means that the settings of the prior function tags can affect the following function
tags. For example, if you were to delete a host group in the [HostGroup] tag, the path settings related
to the deleted host group would also be automatically deleted. If you then write the new settings for
the automatically deleted path in the [LUN] tag or the [WWN] tag, that would cause an error.

LUN Manager Spreadsheet Settings

The following LUN Manager functions can be defined by using Configuration File Loader:

Channel Adapter (CHA) settings allow you to change the PCB mode. See

Setting the CHA

Mode

” on page 152.

Port Settings allow you to change the settings for arbitrated loop-physical address (AL-PA), data
transfer speed (host speed), and topology. You can also change the Secure Manager XP setting.
See

Port Settings

” on page 153.

Host Group Settings allow you to create, delete, or change the host group. See

Setting the Host

Group

” on page 154.

Configuration File Loader

150

Advertising
This manual is related to the following products: