Duplicate volser (volume serial number), Logical volume types, Volume types – HP StorageWorks XP Remote Web Console Software User Manual

Page 41

Advertising
background image

NOTE:

URz does not support operations in which one primary data volume is copied to more

than one secondary data volume, or more than one primary data volume is copied to one secondary
data volume.

Because URz operates on volumes rather than on files, multivolume files require special attention.
For complete duplication and recovery of a multivolume file (for example, a large database file
which spans several volumes), make sure that all volumes of the file are copied to URz secondary
data volume, and use URz to ensure update sequence consistency across this group of secondary
data volume.

Duplicate VOLSER (Volume Serial Number)

When you select Entire as the initial copy option, the URz initial copy operation copies the VOLSER
of the primary data volume to the secondary data volume, and therefore the primary data volume
and secondary data volume of the URz pair will have the same VOLSER. Since the host operating
system does not allow duplicate VOLSERs, the host system administrator must take precautions to
prevent system problems related to duplicate VOLSERs. For example, the URz secondary data
volumes must be defined in the system generation so they do not come online automatically (see
WARNING below).

WARNING!

If the volumes which will become URz secondary data volumes are physically

attached to the same system images as the production volumes which will become the URz primary
data volumes, the following problems can occur:

When a URz pair is released, the old secondary data volume is usually offline. When a host system
is IPL’d (initial program loaded), the operator will be offered both volumes and asked which volume
should be left offline − the old duplicate volser message. This can be confusing and is prone to
error. To avoid duplication of VOLSER,

1. Identify the volumes that will not be accessed by the host system.

2. Perform CHP OFF or some other operation to ensure that the volumes are inaccessible.

3. When performing IPL, you must perform LOAD CLEAR.

Logical Volume Types

The following DKC and DKU emulation types can be used for the URz software.

Table 10 Supported Emulation Types

Support type

Emulation

All CU images that can be used with XP disk array

DKC

All mainframe volumes that can be used with XP disk array

DKU (Drive)

All DKC and DKU (drive) emulation types for XP disk array can be used for URz software. In URz,
the emulation types of primary and secondary data volumes are indicated.

The following CU emulation types can be used for MCUs (primary storage systems) and RCUs
(secondary storage systems): 3990-3, 3990-6, 3990-6E, 2105, 2107, A-65A2, H-65A2, A-65C1,
A-65C2.

The CU emulation type of an MCU can be different from the CU emulation type of the corresponding
RCU.

Requirements and Restrictions for URz

41

Advertising
This manual is related to the following products: