Table 38 Controller power supply output specifications

Voltage Specification

Minimum

Nominal

Maximum

+3.3 VDC

Output Voltage Steady state current

Power

3.23 VDC

3.30 VDC

3.36 VDC 18 A

59.4W

+5.1 VDC

Output Voltage Steady state current

Power

4.80 VDC

5.00 VDC

5.25 VDC 5.0 A

25.5 W

Total Current Total Power

24 A 105.6 W

1.

+3.3 VDC steady state current requires a minimum 5.0-V load of 1 A.

2.

Total power includes 14.0 watts for the internal blower.

Table 39

defines the AC input current and wattage to the controller power supplies.

Table 39 AC input current and wattage

Nominal

Maximum

Input Voltage

Amps

Watts

Amps

Watts

60-Hz input

100 VAC

0.928

94

1.53

150

120 VAC

0.788

94

1.25

148

208 VAC

0.576

97

0.73

146

50–Hz Input

220 VAC

0.616

102

0.69

146

240 VAC

0.573

100

0.64

147

Environmental specifications

There are no controller environmental specifications. See

Environmental specifications

for this information.

Rack specifications

Physical specifications

WARNING!

The weight of the drive enclosure with the elements installed always requires at least two individuals to

move. HP recommends using a fork lift or a hand truck to move an enclosure in the shipping container.

Table 40

through

Table 45

define the dimensions and weights of the 9000-Series and 10000-Series

Enterprise Virtual Array racks.