Disk drive blank, Power supplies and blowers, Power supply and blower assembly components – HP 3000 Enterprise Virtual Array User Manual

Page 51: Operational disk drive status indications, Non-operational disk drive status indications, Table 10, Table 11

Advertising
background image

Table 10 Operational disk drive status indications

Activity

Online

Fault

Description

Flashing

On

Off

Initial startup.

On

On

Off

The drive is online but is not being accessed.

Flashing

Flashing

Flashing

The drive is being located.

Flashing

On

Off

The drive is operational and active.

Table 11 Non-operational disk drive status indications

Activity

Online

Fault

Description

On

On

On

Indicates no connection or the controllers are offline.

Recommended corrective actions:

1.

Check power supplies for proper operation.

2.

If defective, replace disk drive.

On

Off

Flashing

Indicates disk drive error/not active. Recommended

corrective actions:

1.

Verify FC loop continuity.

2.

Replace disk drive.

Disk drive blank

To maintain the proper enclosure air flow, a disk drive or a disk drive blank must be installed in each

drive bay. The disk drive blank maintains proper airflow within the disk enclosure.

Power supplies and blowers

This section describes the function and operation of the disk enclosure power supplies and blowers.

Figure 16

illustrates the major power supply and cooling components.

CXO7489A

1

3

4

5

5

6

2

Figure 16 Power supply and blower assembly components

1. Power supply
2. Status indicator
3. AC Input connector with bail
4. Module latch (wine-colored)
5. Blower tabs (wine-colored)
6. Blower

HP StorageWorks 3000/5000 Enterprise Virtual Array user guide (VCS 4.xxx)

51

Advertising