0.3.en.03 UNRECOVERABLE condition—Blower failure

A

blower

has stopped. The operational blower now operates at high speed and is a single point of

failure. This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your authorized

service representative.

0.3.en.04 UNRECOVERABLE condition—Blower internal

A power supply reported an internal

blower

error that could affect enclosure cooling and cause an

element to fail. HP recommends correcting the problem before the blower fails. This condition report

remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized

service representative.

0.3.en.05 NONCRITICAL condition—Blower missing

A

blower

has been removed or is improperly installed. Even though the blower flaps close to maintain

the proper air flow, the reduced cooling capability can cause overheating, causing an element to fail.

This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized

service representative.

0.3.en.06 UNRECOVERABLE condition—No blowers installed

NOTE:

IMPORTANT
When this condition exists there will be two error messages.
The first message will be 0.3.en.05 and will identify the first

blower

.

The second message will be 0.3.en.06 and will identify the second

blower

.

The EMU cannot detect any installed

blowers

. Shutdown is imminent! The EMU will shut down the

enclosure in seven minutes unless you correct the problem. This condition report remains active until you

correct the problem or the EMU shuts down the power supplies, whichever occurs first.
Complete the following procedure to correct this problem.

1.

Record all six characters of the condition report.

2.

Use the controller shutdown procedure to shut down the controllers.

3.

Contact your authorized service representative.

CAUTION:

An automatic shutdown and possible data corruption may result if the

blower

is removed before

a replacement is available.

Temperature conditions

The format of a temperature condition report is 0.4.en.ec, where:

0.4. is temperature sensor element type

en. is the two-character temperature sensor element

ec is the error code