background image

HSV controller—Manages all aspects of storage system operation, including communications

between host systems and other devices. A pair of HSV controllers is included in Enterprise

Virtual Array.

Rack—A variety of free-standing racks are available.

Physical layout of the storage system

The basic physical components are shown in

Figure 1

. The disk drives are installed in the disk enclosures,

which connect to Fibre Channel (FC) loop switches. The controller pair also connects to the FC loop

switches.

1

3

3

2

CXO7941A

Figure 1 EVA5000 Storage system hardware components

1. Drive enclosures

2. FC device loop switches

3. HSV110 controllers

The hardware components shown in

Figure 1

are discussed in the following sections and in

Storage

System Hardware Components

.

Fibre Channel drive enclosure

Each Fibre Channel drive enclosure includes the following features. For additional information, see

Fibre Channel drive enclosures

.

3U enclosure

Dual-redundant, active-to-active, 2–Gbps FC loops

Fourteen bays for 1–inch FC disks

Environmental Monitoring Unit (EMU)

Dual 2–Gbps FC I/O modules—A and B loops

Dual redundant 500W power supplies and blowers

Dual redundant blowers

For ease of management, the disk drives are referred to by their physical location, the drive bay number.

HP StorageWorks 3000/5000 Enterprise Virtual Array user guide (VCS 4.xxx)

21