13 unrecoverable condition—emu load failure, 14 noncritical condition—emu enclosure address – HP 3000 Enterprise Virtual Array User Manual

Page 130

Advertising
background image

Complete the following procedure to correct this problem:

1.

Record all six characters of the condition report.

2.

Reset the EMU.

3.

Observe the EMU to ensure the error is corrected.

4.

If resetting the enclosure did not correct the problem, contact your HP authorized service

representative.

0.7.01.12 NONCRITICAL condition—EMU cannot read NVRAM data

The EMU is unable to read data from the NVRAM. This condition report remains active until the problem

is corrected.
Complete the following procedure to correct this problem:

1.

Record all six characters of the condition report.

2.

Reset the EMU.

3.

Observe the EMU to ensure the error is corrected.

4.

If resetting the enclosure did not correct the problem, contact your HP authorized service

representative.

0.7.01.13 UNRECOVERABLE condition—EMU load failure

The EMU Field Programmable Gate Array (FPGA) that controls the ESI bus failed to load information

required for EMU operation. This condition report remains active until the problem is corrected.
Complete the following procedure to correct this problem:

1.

Record all six characters of the condition report.

2.

Reset the EMU.

3.

Observe the EMU to ensure the error is corrected.

4.

If resetting the enclosure did not correct the problem, contact your HP authorized service

representative.

0.7.01.14 NONCRITICAL condition—EMU enclosure address

Either the enclosure address is incorrect or the enclosure has no address. Possible causes include a

defective enclosure address bus cable, an incorrectly connected cable, or a defective enclosure address

bus enclosure ID expansion cable. This condition report remains active until the problem is corrected.
Complete the following procedure to correct this problem:

1.

Record all six characters of the condition report.

2.

Remove and reconnect the cable between the address bus enclosure ID expansion cable and the

EMU.

NOTE:

The EMU display may not display a change in condition for up to 30 seconds.

3.

Observe the EMU to ensure the error is corrected.

4.

If the problem is not corrected, remove and reinstall the lower and upper terminators, and all the

enclosure ID expansion cable-to-enclosure ID expansion cables.

5.

Observe the EMU to ensure the error is corrected.

6.

Reset the EMU, then observe the EMU to ensure the error is corrected.

7.

If resetting the EMU did not correct the problem, contact your HP authorized service representative.

130

EMU-generated condition reports