HP XP P9500 Storage User Manual

Page 151

Advertising
background image

Figure 3-5 Hitachi Network Objectplaza Trace Utility 2 Release 2.0

Dialog Box.

2

.

In Number of Files, change the number of integrated trace files.
The default is 4. You can specify a value from 1 to 16.
The value you specify here will apply to n in program-installation-

destination-drive:\Program Files\HITACHI\HNTRLib2\spool
\Hntr2n.log (n indicates a file number).

3

.

In File Size(KB), change the size of an integrated trace file.
The default is 256 (kilobytes). You can specify a value from 8 to 8192.

Specify a value greater than or equal to the setting of Buffer Size(KB).

4

.

In Buffer Size(KB), change the buffer size.
Change the buffer size for the monitoring cycle.
The default is 64 (kilobytes). You can specify a value from 8 to 2048.

Specify a value smaller than or equal to the setting of File Size(KB).

5

.

In Interval Timer(Sec), enter a value to shorten the monitoring cycle.
The default is 10 (seconds). You can specify a value from 1 to 300.

6

.

In Lookout Span(Sec), enter a value to specify the interval for

monitoring the number of messages to be output to the integrated trace

file.
The default is 0 (seconds). You can specify a value from 0 to 3600.
If you specify 0, you cannot adjust the number of messages to be output

because the system ignores the setting of Max Messages / Span.

7

.

In Max Messages / Span, enter a value to specify the maximum

number of messages to be output to the integrated trace file at the

monitoring interval specified in Lookout Span(Sec).

Creating an HDLM Environment

3-83

Hitachi Dynamic Link Manager User Guide for Windows

®

Advertising