Connecting hosts

8Gb per second. The P2000 G3 FC MSA System controller enclosures can also be cabled to support the

Remote Snap replication feature (licensed option) via the FC ports. These models support Fibre Channel

Arbitrated Loop (FC-AL or “loop”) topology by default. Connection mode can be set to loop or

point-to-point. Loop protocol can be used in a physical loop or in a direct connection between two devices.

Point-to-point protocol is used to connect to a fabric switch. P2000 G3 FC MSA System controllers employ

FC ports in either of two capacities:

To connect two storage systems through a Fibre Channel switch for use of Remote Snap replication.

For attachment to FC hosts directly, or through a switch.

The first usage option requires valid licensing for the Remote Snap replication feature, whereas the second

option requires that the host computer supports Ethernet, FC, and optionally, multipath I/O.

Connecting direct attach configurations

P2000 G3 FC MSA System LFF and P2000 G3 FC MSA System SFF support up to four direct-connect

server connections, two per controller module. Connect appropriate cables from the servers’ HBAs to the

controller host ports as described below, and shown in the following illustrations.
To connect the P2000 G3 FC MSA System controller to a server or HBA switch — using the controller’s FC

host ports — select Fibre Channel cables supporting 2/4/8Gb data rates, that are compatible with the

controller module’s host port SFP connector. Such cables are also used for connecting a local storage

system to a remote storage system via a switch, to facilitate use of the optional Remote Snap replication

feature.
The table below maps SFP transceiver data rates to relative fiber optic cable characteristics (i.e., cable

length, multimode fiber type (MMF), and ISO/IEC optical multimode cable performance standards). When

transferring data through FC connections, cable lengths should not exceed the lengths listed for each given

fiber type and performance code within the applicable data rate (2/4/8Gb) class.

Single controller configuration

One server/one HBA/single path

Table 5

Maximum cable lengths for 850nm Fibre Channel SFP transceivers

SFP data

Representative FC cable types

Cable performance code

Data rate MMF FC cable length designators

OM1

OM2

OM3

8Gbps

21m with 62.5μm fiber type

X

50m with 50μm fiber type

X

150m with 50μm fiber type

X

4Gbps

70m with 62.5μm fiber type

X

150m with 50μm fiber type

X

380m with 50μm fiber type

X

2Gbps

150m with 62.5μm fiber type

X

300m with 50μm fiber type

X

500m with 50μm fiber type

X

6Gb/s