HP P2000 G3 FC MSA System User Guide

63

When a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is

logged to the event log.

Power supply module voltage sensors

Power supply voltage sensors ensure that an enclosure’s power supply voltage is within normal ranges.

There are three voltage sensors per power supply.

Onboard temperature 2

0–70°C

None

None

None

Onboard temperature 3

(Capacitor temperature)

0–70°C

None

None

None

CM temperature

5–50°C

5°C,

50°C

0°C,

55°C

None

Table 11

Power supply temperature sensors

Description

Normal operating range

Power Supply 1 temperature

–10–80°C

Power Supply 2 temperature

–10–80°C

Table 10

Controller module temperature sensors (continued)

Description

Normal operating

range

Warning

operating range

Critical operating

range

Shutdown values

Table 12

Voltage sensor descriptions

Sensor

Event/Fault LED condition

Power supply 1 voltage, 12V

< 11.00V

> 13.00V

Power supply 1 voltage, 5V

< 4.00V

> 6.00V

Power supply 1 voltage, 3.3V

< 3.00V

> 3.80V