Alert completion

Alerts are automatically marked as Completed according to the criteria in the following table.

Table 7 Alert completion conditions

Completion criteria

Monitored condition

When current usage is less than or equal to the usage
(%) specified for the alert.

Pool usage for each pool

Journal usage for each journal group

License usage

Sidefile and journal volume usage

The write latency time must be less than or equal to
the time specified by the user for the alert to be com-
pleted.

Write latency time (C/T delta)

When the status of the copy pair transitions out of the
state specified for the alert.

Copy pair status

When all of the pairs contained in the copy group are
marked Completed. (Even if the status of pairs in the
copy group changes again, the copy group alert re-
mains Completed.)

Copy group status

Alert retention

By default, alerts older than 30 days are routinely deleted regardless of whether they have been
completed. As a result, Not Completed alerts older than 30 days are deleted and a new notification
for the alert is sent during the next scheduled monitoring operation.

Alert limits

You can register a maximum of 1,000 alert settings. You can add monitoring targets to existing alert
settings or edit existing alert settings (including deleting monitoring targets). If you specify multiple
monitoring targets for a single alert, the total number of targets specified for all alerts cannot exceed
1,000. Templates can be used to specify alert settings (useful when specifying the same settings for
many targets). You can register a maximum of 10 templates.

To reduce performance impact, the maximum number of detected pairs and pairs listed in an alert
(or email notification) for a copy group is 10, displayed in ascending order of source IDs. When the
number of pairs is greater than 10, the notice

More than 10 pairs were detected

is displayed

in the output.