Adding HP EVAs

To view information about an HP EVA, use the Storage Administrator Portal to add the storage
system and associate it with a HP EVA Command View management server. During the initial
Storage Module for vCenter configuration, add the HP EVAs and HP EVA Command View
management servers in a single step as described in

“Adding HP EVA Command View management

servers” (page 15)

. After the initial configuration, you can add and remove HP EVA and

management server associations by modifying the configuration for either the HP EVA Command
View management server or the HP EVA.

To add HP EVAs:
1.

Access the Storage Administrator Portal.

For instructions, see

“About the Storage Administrator Portal” (page 11)

.

2.

Click Add.

The Add Storage System or Management Server page appears.

3.

Select HP EVA in the Type list, and then click Next.

The Add HP EVA page appears. The Storage Name list shows all available HP EVAs. The
Available HP EVA Command View servers box shows all configured HP EVA Command View
servers that manage the selected HP EVA. The Selected HP EVA Command View servers box
shows all HP EVA Command View servers that the Storage Module for vCenter can use to
manage the selected HP EVA.

4.

Select the storage system that you want to manage.

5.

To add a HP EVA Command View server, select one or more available servers, and then click
Add.

To remove a server, select one or more servers, and then click Remove.

NOTE:

The list of available servers includes only HP EVA Command View management

servers that were added using the procedure

“Adding HP EVA Command View management

servers” (page 15)

.

TIP:

Click Add All or Remove All, respectively, to add or remove all HP EVA Command View

servers.

6.

Click Next.

The Add HP EVA page appears, listing the storage pools on the selected HP EVA.

7.

Select the Full Access check box for one or more storage pools to enable provisioning by the
Storage Module for vCenter.

Storage pools do not need to be assigned Full access if they are not intended to be used for
provisioning operations.

8.

Click Finish.

The storage system is added to the Configured Storage Systems and Management Servers
list.

Adding HP MSA 2000 G2 storage systems

To add an HP MSA 2000 G2 storage system:
1.

Verify that a supported version of the HP MSA 2000 G2 firmware is installed.

For the supported firmware versions, see the HP SPOCK website:

http://www.hp.com/storage/spock

16