• If the iSCSI Initiator is already listed under the Show Initiators command:

i.

Enter the initiator mod command and select the iSCSI Initiator that is about to
do discovery.

ii.

Enable CHAP and enter a CHAP secret. For example:

CHAPsecret01

2.

Enable CHAP for the mpx100/100b iSCSI presented target:
• To enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry using the HP Storage-

Works mpx Manager:

a.

Select the iSCSI Presented Target the initiator will log in to.

b.

Click the Information tab.

c.

Select the Enable CHAP check box.

d.

Enable CHAP and enter a CHAP secret. For example:

hpstorageworks

• To enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry using the

mpx100/100b CLI:

a.

Enter the set CHAP command.

b.

Select the Presented Target the initiator will log in to.

c.

Enable CHAP and enter a CHAP secret. For example:

hpstorageworks

3.

Enable CHAP for the Microsoft iSCSI Initiator.

a.

Click the General tab.

b.

Click Secret in the middle of the screen.

c.

Click Reset.

d.

Enter the mpx100/100b iSCSI Presented Target CHAP secret. For example:

hpstorageworks

e.

Click Discovery.
• For manually discovering iSCSI target portals:

i.

Click Add under Target Portals.

ii.

Enter the IP address of the iSCSI port of the mpx100/100b.

iii.

Click Advanced.

iv.

Select the CHAP Login Information check box.

v.

Enter the CHAP secret for the mpx100/100b discovered iSCSI Initiator in the Target
Secret box. For example:

CHAPsecret01

vi.

Click OK and the initiator completes target discovery.

• Using iSNS for target discovery:

i.

Click Add under iSNS Servers.

ii.

Enter the IP address of the iSNS server.

iii.

Click OK.

f.

Click Targets.

g.

Select the appropriate target for login.

h.

Click Log On.