A redundant mpx100 hard-
ware unit for customers who
require high availability.

The AE324A connectivity op-
tion and an EVA storage sys-
tem to provide high-availabil-
ity multipath connectivity or to
upgrade an existing EVA with
iSCSI connectivity for mul-
tipath

HP StorageWorks EVA iSCSI
Upgrade Option (optional)

AE352A

One mpx100b hardware unit
and the necessary components
to install in any EVA rack.
Supports up to 16 iSCSI initiat-
ors.

An EVA4400 storage system
or to upgrade an existing
EVA4400

HP StorageWorks EVA4400
iSCSI Connectivity Option

AJ713A

A redundant mpx100b hard-
ware unit for customers who
require high availability. Sup-
ports up to 16 iSCSI initiators.

The AJ713A connectivity op-
tion and an EVA4400 storage
system to provide high availab-
ility multipath connectivity, or
order separately to upgrade
an existing EVA4400 with
iSCSI connectivity for mul-
tipath.

HP StorageWorks EVA4400
iSCSI Upgrade Option (option-
al)

AJ714A

Install one upgrade license to
increase the number of iSCSI
Initiators from 16 to 48. Install
a second upgrade license to
increase the number of iSCSI
Initiators from 48 to the maxim-
um supported limit of 150.

For use with the EVA4400
and mpx100b only.

HP StorageWorks EVA4400
iSCSI Connectivity 32 Initiator
Upgrade License (LTU) (option-
al)

T5471A

The following additional equipment is required to configure the EVA or EVA4400 iSCSI option for
fabric iSCSI–Fibre Channel attachment mode:

B-series, C-series, or M-series Fibre Channel switch

Optical small form-factor pluggables (SFPs)

Optical Fibre Channel cables

Contact your HP storage representative for specific switch model support.

EVA and EVA4400 iSCSI connectivity options

An EVA storage system can be configured for simultaneous connectivity to iSCSI and Fibre Channel
attached hosts. Support for iSCSI is provided through a dedicated EVA host port (direct connect) or
shared with Fibre Channel through an existing fabric host port (fabric attach).

Figure 1

illustrates the direct connect iSCSI–Fibre Channel attachment mode configuration. This

configuration is used with an EVA 4000/4100/6x00/8x00 storage system.

Figure 2

illustrates the

direct connect iSCSI-Fibre Channel attachment mode for an EVA4400 storage system.

NOTE:

Direct connect mode requires a dedicated host port on each HSV controller. Unused controller host
ports require loop-back connectors. See

Table 12

on page 42 for more information.

Overview of the EVA and EVA4400 iSCSI connectivity option

22

Advertising
This manual is related to the following products: