Condition report analysis

As described in

Appendix B: EMU Generated Condition Reports

, condition report analysis involves:

1.

Identifying the element.

2.

Determining the major problem.

3.

Defining additional problem information.

Viewing the reporting group feature

Another function of the enclosure address bus is to provide communications within a reporting group. A

Reporting Group (rG) is an HSV110 controller pair and the associated drive enclosures. The controller

pair automatically assigns a unique (decimal) four-digit Reporting Group Number (RGN) to each EMU on

an FC-AL.
Each of the drive enclosures on a loop pair are in one reporting group:

All of the drive enclosures on loop pair 1, both loop 1A and loop 1B, share a unique reporting

group number.

All of the drive enclosures on loop pair 2, both loop 2A and loop 2B, share a unique reporting

group number.

Each EMU collects environmental information from the associated enclosure and broadcasts the

information to reporting group members using the enclosure address bus. Information from enclosures

in other reporting groups is ignored.

Reporting group numbers

The reporting group number (RGN) range is 0000 through 4099, decimal.

0000 is reserved for enclosures that are not part of any reporting group.

0001 through 0015 are RGNs reserved for use by the EMU.

0016 through 4095 are valid RGNs.

4096 through 4099 are invalid RGNs.

The reporting group numbers are displayed on the EMU alphanumeric display as a pair of two-digit

displays. These two displays are identified as rH and rL.

Valid rH displays are in the range 00 through 40, and represent the high-order (most significant)

two digits of the RGN.

Valid rL displays are in the range 00 through 99, and represent the low-order (least significant)

two digits of the RGN.

Viewing a reporting group number

To view a reporting group number:

1.

Press and release the bottom push-button until the alphanumeric display is rG.

2.

To display the two most significant digits of the Reporting Group Number, press and hold the

top push-button unit the display is rH.

3.

Press and release the top push-button to display the first two digits of the RGN.

4.

Press and release the top push-button until the alphanumeric display is rH.

5.

Press and hold the top push-button until the alphanumeric display is rL.

6.

Press and release the top push-button to display the last two digits of the Reporting Group Number.

7.

To exit the display, press and release the bottom push-button until the alphanumeric display is rG.