Installing the sff hot-plug drive cage, Remove the pci riser cage – HP ProLiant SL250s Gen8 Server User Manual

Page 23

Advertising
background image

Operations 23

Installing the SFF hot-plug drive cage

1.

Install the SFF hot-plug drive cage.

2.

Connect the power and Mini-SAS cables to the drive backplane.

3.

Install the server into the chassis ("

Installing the server into the chassis

" on page

31

).

4.

Connect all peripheral cables to the server.

5.

Power up the server (on page

15

).

Remove the PCI riser cage

1.

Power down the server (on page

15

).

2.

Disconnect all peripheral cables from the server.

3.

Remove the server from the chassis (on page

15

).

4.

Remove the SFF hot-plug drive cage ("

Removing the SFF hot-plug drive cage

" on page

22

).

5.

Remove the front GPU cage (on page

16

).

6.

Remove the interposer board (on page

18

).

7.

Remove the front GPU bracket (on page

19

).

8.

Remove the PCI riser cage:

a.

Loosen the thumbscrew securing the PCI riser, and then remove the screws securing the PCI riser

cage.

Advertising