GPU population rules

Observe the following population rules when installing a GPU in the server:

CAUTION:

For proper cooling, be sure that all slots in the GPU cage are occupied by a GPU or

a GPU blank.

Number of GPU

Rear GPU cage
bottom bay (PCIe x16

slot 1 = GPU 1)

Rear GPU cage top bay
(PCIe x16 slot 2 = GPU

2)

Front GPU cage
(PCIe x16 slot 3 = GPU 3)

1

GPU blank

GPU blank

Yes

2

GPU blank

Yes

Yes

3

Yes

Yes

Yes

Installing GPU brackets

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the

internal system components to cool before touching them.

1.

Power down the server (on page

15

).

2.

Disconnect all peripheral cables from the server.

3.

Remove the server from the chassis (on page

15

).

4.

To install GPU in front cage:

a.

Remove the front GPU cage (on page

16

).

Advertising