GPU population rules
Observe the following population rules when installing a GPU in the server:
CAUTION:
For proper cooling, be sure that all slots in the GPU cage are occupied by a GPU or
a GPU blank.
Number of GPU
Rear GPU cage
bottom bay (PCIe x16
slot 1 = GPU 1)
Rear GPU cage top bay
(PCIe x16 slot 2 = GPU
2)
Front GPU cage
(PCIe x16 slot 3 = GPU 3)
1
GPU blank
GPU blank
Yes
2
GPU blank
Yes
Yes
3
Yes
Yes
Yes
Installing GPU brackets
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
1.
Power down the server (on page
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis (on page
4.
To install GPU in front cage: