Figure 75 example of wwnn, 75 example of wwnn, Table 37 – HP StorageWorks XP Remote Web Console Software User Manual

Page 163: Figure 75

Advertising
background image

Hitachi TrueCopy for z/OS user guide 163

Figure 75

Example of WWNN

NOTE:

The parameter of PRIM and SEC of CDELPATH command are indicated as same as the parameter

of CESTPATH command.
If the subsystem is connected to the former type subsystem that does not support the Fibre Channel

interface, a unit check is reported.

The following table gives the XP12000/XP10000 system adapter ID (SAID) values for the CESTPATH LINK

parameter.

The last two digits of the link parameter must specify the logical CU number (00-1F for an

XP12000/XP10000, 00-0F for an XP256).

For 3990 controller emulation, the first two digits can be 00, 01, or 02. This option controls freeze as

follows:
00 = use mode 104
01 = freeze enabled
02 = freeze disabled

For 2105 or 2107 emulation, the first two digits must be 00. The CGROUP option of the CESTPATH

command is used to control freeze for 2105 or 2107 emulation.

Table 37

SAID Values for LINK parameters (ports) (FRONT CL1)

Package

Location

Port

SAID*

Package

Location

Port

SAID*

Package

Location

Port

SAID*

Package

Location

Port

SAID*

1E

CL1-A

X'0000' 1G

CL1-J

X'0008' 1K

CL9-N X'008C' 1B

CL9-E

X'0084'

(Basic)

CL3-A X'0020' (Add 2)

CL3-J

X'0028' (Add4)

CLB-N X'00AC' (Add6)

CLB-E

X'00A4'

CL5-A X'0040'

CL5-J

X'0048'

CLD-N X'00CC'

CLD-E

X'00C4'

CL7-A

X'0060'

CL7-J

X'0068'

CLF-N X'00EC'

CLF-E

X'00E4'

CL1-B

X'0001'

CL1-K

X'0009'

CL9-P

X'008D'

CL9-F

X'0085'

CL3-B

X'0021'

CL3-K

X'0029'

CLB-P

X'00AD'

CLB-F

X'00A5'

CL5-B

X'0041'

CL5-K

X'0049'

CLD-P

X'00CD'

CLD-F

X'00C5'

CL7-B

X'0061'

CL7-K

X'0069'

CLF-P

X'00ED'

CLF-F

X'00E5'