Figure 36 usage monitor window, Script operations window, 36 usage monitor window – HP StorageWorks XP Remote Web Console Software User Manual

Page 78

Advertising
background image

78

Hitachi TrueCopy z/OS for HP XP12000/XP10000 and SVS 200 storage systems

NOTE:

You must use XP Command View Advanced Edition Software or XP Remote Web Console in

Modify mode to perform TC390 operations. Users in view mode can only view TC390 information.

Figure 36

Usage Monitor window

The Usage Monitor window displays the following information:

Status: Displays Running when monitoring is on and displays Stop when monitoring is off. When

monitoring is stopped, the usage monitor graph is closed. The usage monitor graph can only be

displayed when monitoring is running.

Rate: Displays the data collection rate for usage monitoring (default = 5). When monitoring is stopped,

the default value (5) is displayed in the Rate box.

Operation: Used to select the usage monitor operation.

Update: Displays the most recent data sample time of the data on the graph.

Script Operations window

TC390 running on XP Command View Advanced Edition Software or XP Remote Web Console supports

scripting for managing pre-defined TC390 operations. The TC390 scripting function defines multiple

TC390 operations in a text file that XP Command View Advanced Edition Software or XP Remote Web

Console reads and executes as a batch file. Use the scripting function to perform a series of TC390

operations without having to issue the commands separately. Using TC390 scripting, you can set up and

execute a large number of TC390 commands within a short period of time. Use the TC390 scripting

function to:

Save time by executing multiple TC390 operations with a single command.

Run a series of predefined and tested TC390 operations after hours or overnight.

Allow a non-resident system administrator to set up and start an entire day’s worth of TC390 operations

in the limited time that the administrator is on-site.

This section describes the selection and execution of an existing TC390 script file. ”

TrueCopy scripting

” on

page 191 describes and specifies the requirements for the TC390 script files.

Advertising