Rmf pprc link-path statistical information support – HP StorageWorks XP Remote Web Console Software User Manual

Page 42

Advertising
background image

42

Hitachi TrueCopy z/OS for HP XP12000/XP10000 and SVS 200 storage systems

Mode 104 must be ON for 3990 controller emulation (not valid for 2105 and 2107 emulation).
For more information on XP12000/XP10000 SVP system option mode related to TC390 operations,

see

Table 3

on page 18.

Mode 104 must be set before any TC390 pairs are established in a GDPS environment. If TC390 pairs

have already been established, you must delete all pairs and logical paths (CDELPAIR, CDELPATH),

change the SSIDs and mode settings on the MCUs and RCUs, and then re-establish the paths and pairs

(CESTPATH, CESTPAIR). Installation of mode 64 is nondisruptive and can be performed at any time.

RMF PPRC Link-path statistical information support

When you use z/OS Resource Measurement Facility (RMF), and if you specify the IBM TotalStorage

Enterprise Storage Server (ESS), you can acquire the PPRC Fibre Link-path statistical information. For further

information on the PPRC Link-path statistical information acquisition, see IBM publications.

Table 13

and

Table 14

give the XP12000/XP10000 system adaptor ID(SAID) values for the LINK

parameters (ports) that are displayed when you acquire the PPRC Link-path statistical information using

RMF.

NOTE:

The XP12000/XP10000 system adaptor ID(SAID) values in

Table 13

and

Table 14

are different

from the ones for the LINK parameters of the TSO commands (see

Table 34

and

Table 35

).

NOTE:

If you acquire the PPRC Fibre Link-path statistical information using RMF, and if the total data size

for the interval for which you acquire the data is 100 kB and below, zero may be reported for the data

size. Even if the data is not updated by host I/O during TCzA operations, data size is reported. This is

because the recordset that does not have data is sent from MCU to RCU. In this case also, if the total data

size for the interval for which you acquire the data is 100 kB and below, zero may be reported for the

data size.

Table 13

SAID Values for LINK Parameters (ports) of RMF PPRC Link-path Statistical Information (FRONT CL1)

Package

Location

Port

SAID*

Package

Location

Port

SAID*

Package

Location

Port

SAID*

Package

Location

Port

SAID*

1E

CL1-A

X'0000' 1G

CL1-J

X'0020' 1K

CL9-N X'0070' 1B

CL9-E

X'0050'

(Basic)

CL3-A X'0001' (Add 2)

CL3-J

X'0021'

(Add4)

CLB-N X'0071'

(Add6)

CLB-E

X'0051'

CL5-A X'0004'

CL5-J

X'0024'

CLD-N X'0074'

CLD-E

X'0054'

CL7-A

X'0005'

CL7-J

X'0025'

CLF-N X'0075'

CLF-E

X'0055'

CL1-B

X'0008'

CL1-K

X'0028'

CL9-P

X'0078'

CL9-F

X'0058'

CL3-B

X'0009'

CL3-K

X'0029'

CLB-P

X'0079'

CLB-F

X'0059'

CL5-B

X'000C'

CL5-K

X'002C'

CLD-P

X'007C'

CLD-F

X'005C'

CL7-B

X'000D'

CL7-K

X'002D'

CLF-P

X'007D'

CLF-F

X'005D'

CL1-C

X'0002'

CL1-L

X'0022'

CL9-Q X'0072'

CL9-G X'0052'

CL3-C X'0003'

CL3-L

X'0023'

CLB-Q X'0073'

CLB-Q X'0053'

CL5-C X'0006'

CL5-L

X'0026'

CLD-Q X'0076'

CLD-G X'0056'

CL7-C

X'0007'

CL7-L

X'0027'

CLF-Q X'0077'

CLF-G X'0057'

CL1-D

X'000A'

CL1-M X'002A'

CL9-R

X'007A'

CL9-H X'005A'

CL3-D X'000B'

CL3-M X'002B'

CLB-R

X'007B'

CLB-H X'005B'

CL5-D X'000E'

CL5-M X'002E'

CLD-R

X'007E'

CLD-H X'005E'

CL7-D

X'000F'

CL7-M X'002F'

CLF-R

X'007F'

CLF-H

X'005F'

Advertising
This manual is related to the following products: