Table 56 example of createhrcpair parameters, 56 example of createhrcpair parameters – HP StorageWorks XP Remote Web Console Software User Manual

Page 196

Advertising
background image

196 Hitachi TrueCopy z/OS for HP XP12000/XP10000 and SVS 200 storage systems

CT group list (numeric): consistency group number (0x00 - 0x7F). For async pairs you must specify this

parameter. For sync pairs you must omit this parameter.

Priority list (numeric): priority of initial copy operation (1-256); default = 32.

Fence level list (string): “N” or “Never”, “S” or “Status” “D”, or “Data” = default = “Never”. For async

pairs you must either specify N (never) or omit this parameter.

CFW flag list (numeric): 0 = copy CFW data to R-VOL; 1 = only M-VOL; default = 1.

DFW flag list (numeric): 0 = DFW not required; 1 = DFW required; default = 0. Must be omitted for

async pairs.

Error level list (string): “G” = group; “V” = volume; default = G. For sync pairs you must omit this

parameter.

Time-Saving Mode flag: “Yes” = The Use Time-Saving Mode option is enabled; “No” = The Use

Time-Saving Mode option is disabled; default = “Yes”. This parameter is a non-list type and only one

value can be specified.

Differential management measurement flag list (string): The differential between the volumes is

managed in Cylinder (“Cylinder” or “C”) or in Track (“Track” or “T”). When “Auto” or “A” is specified,

the disk array selects the differential management measurement (cylinder or track) automatically. The

default is Auto. If the disk array does not support the “Auto” option, “Track” is specified as the default.

The following CreateHrcPair command output shows an example of the pair macro commands needed to

create the specified pairs with the parameters listed in the following table.

CAUTION:

When using the CreateHrcPair command to create more than one pair, make sure to keep

each line within the maximum line length (320 bytes). For script command restrictions and parameters, see

Script file requirements

” on page 194.

Table 56

Example of CreateHrcPair parameters

Parameter

Value

Parameter

Value

M-VOL

_ilDevA

CT group

[omit – N/A]

Serial number (RCU)

_slWorkA

Priority

_ilWorkA

SSID (RCU)

11

Fence level

Never

R-VOL _ilDevB

CFW

flag

0

Initial copy pace

_slWorkB

DFW flag

1

Initial copy mode

E

Error level

[omit – N/A]

Sync level

S0, S0, S0

Time-Saving Mode

[omit – default]

Advertising
This manual is related to the following products: