162 Hitachi TrueCopy z/OS for HP XP12000/XP10000 and SVS 200 storage systems

The following table describes the CESTPATH LINK parameter for the Fibre Channel interface.

The syntax for the CESTPATH command (Fibre Channel Interface) is:

CESTPATH DEVN(X'dev#') PRIM(X'ssid'' WWNN X'lss') SEC(X'ssid' WWNN X'lss')
LINK(X'aabbccdd') [CGROUP (YES|NO)]

WWNN (World Wide Node Name) is the unique number for the controller and is indicated as shown in

Figure 75

.

Table 35

CESTPATH LINK parameter (ESCON interface)

LINK Parameter

Fibre Channel Interface

aa
First two digits of SAID,
see

Table 37

on

page 163

.

Bit 0-3: RCU controller ID

x2-xF: Number stands for RCU

controller ID.
(x’4’ is specified.)

Bit 4-7: FREEZE option

x0:keep the status
x1:Enabled
x2:Disabled

When there are several paths, the same

values must be specified for all the

paths.

bb
Second two digits of SAID,

see

Table 37

on

page 163.

MCU port number (0x00-0x1ff)

cc

RCU port number (0x00-0x1ff)

dd

CU number (0x00-0x3f)

Table 36

CESTPATH LINK parameter (Fibre Channel interface)

LINK Parameter

Details

aabb

SAID of MCU (x'00 and the port
number

ccdd

SAID of RCU (x'00 and the port
number)