Iea494i message, Iea491e message – HP StorageWorks XP Remote Web Console Software User Manual

Page 180

Advertising
background image

180 Hitachi TrueCopy z/OS for HP XP12000/XP10000 and SVS 200 storage systems

NOTE:

If PPRC Support = No is selected on the RCU Option window, the host generates the system

console message that includes the SIM instead of the IEA494I or IEA491E message.

IEA494I message

Whenever a TC390 pair status changes, with the exception of the TC390A transition states suspending

and deleting, the MCU reports state-change-interrupt (SCI) to all hosts. In response to the SCI, the IEA494I

system console message is generated (if supported by the host). The XP12000/XP10000 reports SCI for

both online and offline devices, but the host system does not generate console messages for offline devices.

Therefore, the IEA494I message is never generated with a TC390 R-VOL device address. The following

figure shows an example of an IEA494I message.

The XP12000/XP10000 MCU reports SCI for all TC390A pairs whose status has changed, regardless

of the Group/Volume option of the suspend or delete pair operation (if the status change was

user-requested).

The XP12000/XP10000 MCU reports SCI for all TC390 M-VOLs (synchronous only) that are in the SCP

state due to the CGROUP/FREEZE command. As shown in the following figure, this IEA494I message

indicates the extended long busy state.

The XP12000/XP10000 MCU reports SCI for all TC390 M-VOLs (synchronous only) that are suspended

due to the CGROUP/RUN command. This IEA494I message indicates the extended long busy state.

When the FREEZE option is enabled, the XP12000/XP10000 MCU reports SCI for a TC390 pair that is

suspended due to a failure. When the host supports GDPS, this IEA494I message with extended long

busy triggers the CGROUP (FREEZE/RUN) command.

Output Example: IEA494I Message with Extended Long Busy State

IEA491E message

When a TC390 pair is suspended due to a failure, the XP12000/XP10000 MCU reports SCI as well as

unit check status and sense bytes with F/M = FB. In response to the F/M=FB sense bytes, the IEA491E

system console message is generated (if supported by the host). The following figure shows an example of

an IEA491E message.

NOTE:

If the host supports GDPS and the FREEZE option is enabled, the IEA494I system console message

with extended long busy, which was generated in response to the SCI, triggers the CGROUP

(FREEZE/RUN) command.

Output Example: IEA491E Message

XP12000/XP10000 response characteristics to failure conditions

The XP12000/XP10000 supports the CGROUP command in the GDPS environment by performing

PPRC-compatible actions and returning PPRC-compatible messages to failure conditions. The following

figure shows the failure conditions and the following table describes the response characteristics of the

XP12000/XP10000 to these failure conditions.

IEA494I 0FC3,RD0FC3,PPRC PAIR SUSPENDING,SSID=0FC0,CCA=03,EXTENDED LONG BUSY STATE

IEA491E DSLFC0,PPRC SUSPENDED, SECONDARY NOT READY, INTERVENTION_REQUIRED,
(PRI)SER=0113-90797,CCA=00 (SEC)SER=0113-90217,CCA=