R-VOL read option

For additional flexibility, TC390 offers a special R-VOL read option. The HP representative enables the

R-VOL read option on the RCU (mode 20). You can use the TC390 R-VOL read option to read a TC390

R-VOL only while the pair is suspended, without having to delete the pair. The RCU will change only the

VOLSER of the suspended R-VOL so that the R-VOL can be online to the same host as the M-VOL while the

pair is suspended. All other write I/Os will be rejected by the RCU. The MCU copies the M-VOL VOLSER

back onto the R-VOL when the pair is resumed. When the R-VOL read option is not enabled and/or the

pair is not suspended, the RCU rejects all read and write I/Os to a TC390 R-VOL. If you need write access

to an R-VOL, you must delete the pair.

NOTE:

For 2105 or 2107 controller emulation, the CSUSPEND command to the R-VOL of a suspended

TC390 pair will be rejected when the TC390 R-VOL read option is used.

Difference management

The differential data (updated by write I/Os during split or suspension) between M-VOL and R-VOL is

stored in each cylinder bitmap. When a deleted/suspended pair is resumed (Resume Pair), the MCU

merges the M-VOL and R-VOL bitmaps, and the differential data is copied to the R-VOL. The unit of data

stored in the bitmap is Track or Cylinder. When adding a pair (Add Pair), you can select Track or Cylinder

and you can also confirm the unit.

When you add a pair with the setting of Track, the number of pairs you can create is restricted. If you

create the pairs more than the restricted number, a pair is automatically added with Cylinder. You can

restrict the automatic change of the setting. Before using this function, contact your HP account support

representative.
The restriction of the number of pairs depends on the capacity of the volumes used for the pairs. Both of the

MCU and RCU are restricted.
The number of bitmap area in the disk array is 10,476. You can calculate the number of bitmap area. If the

calculated bitmap area exceeds the number of bitmap area in the disk array, adding pairs operation is

restricted.

To calculate the number of bitmap area, you can use the following equation:

( ( (Number of Cylinders * 15) / 75,136) ) - 1

Table 5

Operation of the unit of data stored in bitmap

Program

The Unit of Data Stored in Bitmap

Confirmation

Default (Auto)

1

1. Default (Auto) means that Track or Cylinder is automatically set according to the capacity (number of cylinders or number

of cylinders set by VLL) of the volumes used for the pairs. For volumes that have 10,019 cylinders or more, Cylinder is set.

For other volumes, Track is set.

Track

Cylinder

XP Command View

Advanced Edition

Software or XP

Remote Web

Console

Available

Available

Available

Available

PPRC TSO

Not available

Not available

Not available

Not available

Table 6

Maximum Pairs by Emulation Type, when pairs are created without custom volumes

Emulation

Type

Number of

Cylinders

Number of

Bitmap Areas

Maximum Number of Pairs
(Added Shared Memory:

1 set)

Maximum Number of Pairs
(Added Shared Memory:

2 sets)

3380-J

885

1

11,605

16,384

3380-E

1,770

1

11,605

16,384