Drive led definitions – HP ProLiant BL460c Gen8 Server Blade User Manual

Page 7

Advertising
background image

Component identification 7

Item Description

Status

Off = Normal (System is in standby)

2

Power On/Standby

button and system
power LED

Solid Green = System is powered on.

Flashing Green = System is waiting to power on; Power On/Standby button is
pressed.

Solid Amber = System is in standby; Power On/Standby button service is

initialized.
Off and the Health Status LED bar is off = The system has no power.

Off and the Health Status LED bar is flashing green = The Power On/Standby

button service is being initialized.

3

UID LED

Solid Blue = Identified
Flashing Blue = Active remote management

Off = No active remote management

4

FlexibleLOM LED

Green = Network linked
Flashing Green = Network activity

Off = No link or activity

Drive LED definitions

Item LED

Status

Definition

1

Locate

Solid blue

The drive is being identified by a host application.

Flashing blue

The drive carrier firmware is being updated or requires an update.

2

Activity ring

Rotating green

Drive activity

Off

No drive activity

3

Do not remove

Solid white

Do not remove the drive. Removing the drive causes one or more of

the logical drives to fail.

Off

Removing the drive does not cause a logical drive to fail.

4

Drive status

Solid green

The drive is a member of one or more logical drives.

Flashing green

The drive is rebuilding or performing a RAID migration, stripe size

migration, capacity expansion, or logical drive extension, or is
erasing.

Flashing

amber/green

The drive is a member of one or more logical drives and predicts

the drive will fail.

Flashing amber The drive is not configured and predicts the drive will fail.

Solid amber

The drive has failed.

Off

The drive is not configured by a RAID controller.

Advertising