iLO

If after discovery runs, you can see the CMS, but not the iLO associated with it, check the following:

Be sure both the IP of the CMS and the iLO are discovered.

Be sure to enter the iLO credentials on the Options

→Security→Credentials→Global Credentials.

After setting the credentials, rerun discovery.

Run Configure or Repair Agents to be sure SNMP is configured on iLO and set correctly at
the CMS.

-------------------------------------------------------------
Deployment to an iLO with Trust Platform Module (TPM) enabled on the server will fail. You can
only deploy iLO firmware if TPM is disabled.

Linux servers

When a Linux server is discovered as an unmanaged system:
1.

Be sure to make the changes similar to the following in the /etc/hosts file on the discovered
system before installing agents:

#Do not remove the following line, or various programs
#that require network functionality will fail.
127.0.0.1 localhost
172.24.30.34 HPSIM.wbemqa.com HPSIM

Note: Replace the IP address, host name, and alias previously listed with your localhost IP
address, DNS name, and host name.

2.

Install agents.

3.

Verify that the following lines are entered in the /etc/snmp/snmpd.conf file. If not, stop
the SNMP service, enter them manually, and restart the SNMP service.

rwcommunity private
rocommunity public

Note: The community strings used should match those community strings on the CMS.

After completing these steps, the system is discovered properly.
-------------------------------------------------------------
To discover detailed information for Linux running on ProLiant systems, you can do one of the
following:

Install the Linux ProLiant agents on the system.

Update the snmpd.conf file. If you choose this option and do not update the snmpd.conf
file, LINUX appears in the Operating system name column on the system table view page,
instead of the true operating system name, such as Red Hat Advanced Server.

To solve this issue:
1.

Stop the SNMP daemon.

2.

Add the following line to the /etc/snmp/snmpd.conf file:

rocommunity public

3.

Restart SNMP.

Enclosure table view page

iLO's do not appear in the enclosure table view page. However, to access the iLO from this view,
click the status icon in the MP column of the associated server.

Event

When you subscribe for WBEM events from either the command line (mxwbemsub) or the GUI
(Options

→Events→Subscribe to WBEM Events), you might receive the error message String

index out of range

.