7

Valid RAID Level Changes

To make practicable RAID level changes with HP NetRAID, observe the possible valid RAID level
changes listed in the following table when altering a physical drive or logical drive.

Existing RAID
Configuration

Valid RAID

Configuration Change

Configuration Event

RAID 3 or RAID 5 Optimal

RAID 3 or RAID 5 Optimal

Expanding capacity

RAID 3 or RAID 5 Optimal

RAID 0

Stopping parity

RAID 3 or RAID 5 Optimal

RAID 0

Deleting a drive, or adding drives

RAID 3 or RAID 5

RAID 3 or RAID 5 Optimal

If a drive fails, you can configure an
Optimal RAID 0 system.

RAID 1 Optimal

RAID 3 or RAID 5 Optimal

Adding drives

RAID 1 Optimal

RAID 0

Adding drives, or deleting a drive

RAID 1 Degraded

RAID 0

If a drive fails, you can configure an
Optimal RAID 0 system

RAID 0

RAID 3 or RAID 5 Optimal

Adding drives

RAID 0

RAID 1 Optimal

Adding a drive

RAID 0

RAID 0

Adding drives

HP NetRAID Valid RAID Configuration Changes

C. Monitor Feature

Monitors send SNMP error messages to the HP NetRAID Assistant or the HP NetServer Assistant if
the disk array is not functioning properly.

Disk array monitors are provided for all operating systems. For information on SNMP agents (the
part of the system that performs information preparation and exchange on behalf of a client or
server) or server standalone, refer to HP NetServer Assistant. Monitors are installed with the
NetRAID utilities, and are included as part of the utility installation process.

Refer to your operating system information and the section Installing HP NetRAID Utilities for
information on installation. Refer to the section Troubleshooting for a list of monitor alerts.

D. Check Consistency Feature

Check Consistency ensures that parity data or mirroring is correct for the selected drives. RAID
levels 3, 5, 30 and 50 use an extra drive to store parity data blocks. Parity is checked between these
parity data blocks and the selected drives when you select this option. RAID levels 1 and 10 use
duplicate data drives; the duplicate data is verified.

NOTE

It is strongly

recommended that you run a regular consistency check (every 2 - 4

weeks) to ensure that good blocks on hard disk drives are reallocted. Bad blocks
which accumulate can cause rebuild failures is a drive fails.