HP NetRAID 1 Controller User Manual

Page 36

Advertising
background image

32

Terminate Wide Channel: Enables Wide termination for the selected channel. This is
required if the HP NetRAID or HP NetRAID-1 adapter is at one end of the SCSI bus for the
selected channel. The default setting is Wide Termination.

Disable Termination: Disables termination on the adapter for the selected channel. This
option should be used if the selected SCSI channel is terminated with Wide devices at both
ends.

View Parameters: Displays the termination and active status of the selected channel.

Battery Backup (HP NetRAID Only)

View the Battery Backup properties from this option. The properties of your battery pack should be
identical or similar to the following properties.

Battery Card

Present

Battery Pack

Present

Temperature

Good

Voltage

Good

Fast Charging

Completed

Charge Counter

1

Reset Charge Count Cycles

Yes

No

NOTE

The HP NetRAID-1 adapter does not have a battery backup module. This menu
item will produce an error message (missing battery) if accessed with the HP
NetRAID-1 adapter. Disregard the message for NetRAID-1 adapters.

Format

Choose the Format option to low-level format one or more physical drives.

Since most SCSI disk drives, including all HP drives, are low-level formatted at the factory, this step
is usually not necessary. You typically must format a disk only if:

The disk drive was not low-level formatted at the factory.

There is an excessive number of media errors detected on the disk drive.

You do not need to use the Format option if you simply want to erase existing information on your
SCSI disks, such as a DOS partition. That information is erased when you initialize the logical
drive(s).

You cannot format a drive that is online.

Rebuild

Choose the Rebuild option to rebuild one or more failed disk drives.

Advertising
This manual is related to the following products: