E. exiting hp netraid express tools – HP NetRAID 1 Controller User Manual

Page 60

Advertising
background image

56

3. Choose the Rebuild option from the action menu and respond to the confirmation prompt.

Rebuilding can take some time, depending on the drive capacity.

4. When rebuild completes, press any key to return to the previous menu.

Manual Rebuild – Batch Mode

1. Choose Rebuild from the HP NetRAID Config Management Menu. A device selection

window is displayed showing the devices connected to the current adapter. The failed drives
have FAIL indicators.

2. Press the arrow keys to highlight all drives to be rebuilt. Press the spacebar to select the

highlighted physical drive for rebuild.

3. After selecting the physical drives, press F10 and select Yes at the confirmation prompt. The

indicators for the selected drives changes to REBLD. Rebuilding can take some time,
depending on the number of drives you have selected and the drive capacities.

4. When rebuild is complete, press any key to continue. Press Esc to return to the Management

Menu.

Using a Pre-loaded SCSI Drive "As-is"

NOTE

To use a pre-loaded drive in the manner described here, you must make it the first
logical drive defined (for example: LD1) on the adapter to which it is connected.

You may have a SCSI disk drive that is already loaded with software. The drive may be a boot disk
containing an operating system. You can use the adapter as a SCSI adapter for such a drive by
performing the following steps:

1. Connect the SCSI drive to one of the channels on the HP NetRAID or HP NetRAID-1

adapter, with proper termination and Target ID (TID) settings.

2. Boot the NetServer and start HP NetRAID Express Tools by pressing Ctrl M.

3. Choose Easy Configuration from the Configure menu.

4. Use the arrow keys to highlight the pre-loaded drive.

5. Press the spacebar. The pre-loaded drive should now become an array element.

6. Press Enter. You have now declared the pre-loaded drive as a one-disk array. Display the

logical drive configuration screen.

7. Set the Read Policy and Cache option on the Advanced menu.

8. Exit the Advanced menu. Highlight Accept and press Enter.

9. Press Esc and choose Yes at the Save prompt.

10. Exit BIOS setup and reboot.

11. Set the host system to boot from SCSI, if such a setting is available.

E. Exiting HP NetRAID Express Tools

To exit HP NetRAID Express Tools, press Esc at the Management Menu display. Choose Yes at the
prompt. You must then reboot the NetServer.